    摘要:

    在热带海岛特殊气候条件下,低碳园区存在着新能源出力波动大、占比高、调节能力有限、空调负荷全年重载等特点.面对园区源荷不匹配导致的供电不稳定问题,目前大多研究运用储能来平抑波动,削峰填谷,但对热带海岛环境下导致的独特源荷特性涉及较少.为此,本文提出一种适应园区特性的广义储能多时间尺度优化调度策略.首先,构建了热带海岛气象下独特的源荷模型,并结合地域特征进行适配;其次,建立了长-中-短三层时间尺度协调架构:长期尺度以虚拟电厂经济性最优为目标,中期尺度基于滚动优化修正预测偏差,短期尺度旨在保障系统动态响应与鲁棒性;最后,为了验证所提方法的有效性,本文结合海南省某地园区负荷特性,以某用户为例进行仿真验证.相比传统双层优化调度,所提方法通过峰谷套利充储策略与优化,使日累计总运行成本降低了27.72%,下降了9649.3元,在用户侧储能充分参与下,实现了经济可靠运行.

    Abstract:

    Under the unique climatic conditions of tropical islands, low-carbon parks are characterized by severe fluctuations and high penetrations of renewable energy, limited regulation capacity, and year-round heavy air-conditioning loads. To address the power supply instability caused by source-load mismatches within the parks, most current studies employ energy storage systems to smooth fluctuations and achieve peak shaving and valley filling. However, few studies have investigated the distinct source-load characteristics induced by the tropical island environment. To this end, this paper proposes a multi-time-scale optimal scheduling strategy for generalized energy storage tailored to the specific characteristics of such parks. First, a unique source-load model under tropical island meteorological conditions is constructed and adapted to regional features. Second, a three-tier time-scale coordination framework is established: the long-term scale aims to optimize the economy of the virtual power plant; the medium-term scale corrects prediction deviations based on rolling optimization; and the short-term scale ensures the dynamic response and robustness of the system. Finally, a case study of a user in a park in Hainan Province is presented to verify the proposed method. Simulation results indicate that, compared to traditional bi-level optimization scheduling, the proposed strategy reduces the total daily operating cost by 27.72% (9,649.3 CNY) through optimized peak-valley arbitrage. Consequently, economic and reliable operation is realized with the active participation of user-side energy storage.□

    参考文献
    相似文献
    引证文献
引用本文
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-03-22
  • 最后修改日期:2026-08-10
  • 录用日期:2026-08-14
  • 在线发布日期: 2026-09-03
  • 出版日期:
文章二维码